Each cultivar already knows how much water it wants. We size the header and the poly mainline so pressure holds at the far end. Keep flow under 5 feet a second and tape above 8 psi. One zone at a time is the usual program; everything at once is the stress test.

Mainline residual pressureFriction in PE pipe
Supply · source
Peak zone
4.2 GPM
All zones
16.89 GPM
Supply
10 GPM
Headroom
5.8 GPM

All zones inside velocity ≤ 5 ft/s and supply. Sequential program OK.

Zones · hydraulic audit

ZONEBEDSEMITTERSDEMANDUTILHEADERΔPVSTATUS
A LETTUCE46004.2 GPM42%0.8 psi2.53 fpsOK
B CARROT11501.05 GPM11%0.1 psi0.63 fpsUPSIZE ½ in
C BRASSICA33002.3 GPM23%0.2 psi1.38 fpsUPSIZE ½ in
D SOLANUM21501.25 GPM13%0.1 psi0.75 fpsUPSIZE ½ in
E CUCURBIT21000.96 GPM10%0 psi0.58 fpsUPSIZE ½ in
F HERB34502.73 GPM27%0.3 psi1.64 fpsUPSIZE ½ in
G GREENS34502.3 GPM23%0.2 psi1.38 fpsUPSIZE ½ in
H ALLIUM23002.1 GPM21%0.2 psi1.26 fpsUPSIZE ½ in

Sized so water stays under 5 ft/s and header loss under 3 psi. Demand comes from the crop's emitters.